Mastercool 90068-2V-220SVB — 227 L/min Vacuum Pump Solenoid Valve 220V

Mastercool 90068-2V-220SVB — 227 L/min Vacuum Pump Solenoid Valve 220V

£680.36 GBP
Skip to product information
Mastercool 90068-2V-220SVB — 227 L/min Vacuum Pump Solenoid Valve 220V

Mastercool 90068-2V-220SVB — 227 L/min Vacuum Pump Solenoid Valve 220V

£680.36 GBP
Shipping calculated at checkout.

227 Litre/Min Two-Stage Vacuum Pump with Solenoid Valve — 220V 50/60Hz

The Mastercool 90068-2V-220SVB is a professional two-stage vacuum pump featuring 227 litre/min free air displacement (at 60Hz), solenoid valve, and vacuum gauge. Designed for HVAC/R system evacuation, this 3/4 HP pump achieves 15 microns ultimate vacuum for thorough moisture and air removal. Supplied with 220V cable (Schuko plug) for European markets.

Key Features

  • Two-Stage Design: Superior vacuum performance
  • 227 L/min Displacement: 227 lit/min at 60Hz, 189 lit/min at 50Hz
  • 15 Microns Ultimate Vacuum: Deep vacuum for thorough evacuation
  • Solenoid Valve: Automatic shut-off when pump stops
  • Vacuum Gauge: Monitor vacuum levels during operation
  • 3/4 HP Motor: Powerful, reliable performance
  • Dual Voltage: 220V 50/60Hz operation
  • 1440 RPM: Optimal pump speed
  • Schuko Power Cord: European standard plug
  • Professional Quality: Built for demanding HVAC/R service

Technical Specifications

  • Model: 90068-2V-220SVB
  • Type: Two-stage vacuum pump with solenoid valve
  • Number of Stages: 2
  • Free Air Displacement: 227 lit/min (60Hz), 189 lit/min (50Hz)
  • Ultimate Vacuum: 15 microns*
  • Motor: 3/4 HP
  • Pump Speed: 1440 RPM
  • Electrical: 220V / 50/60Hz
  • Power Cord: 220V cable with Schuko plug
  • Weight: 15.76 kg (34.75 lbs)
  • SKU: 90068-2V-220SVB
  • HS Code: 84148080

* PLEASE NOTE: The micron readings on all vacuum pumps represent optimal laboratory conditions. Field conditions may vary from these readings.

Applications

  • HVAC/R system evacuation
  • Air conditioning installation
  • Refrigeration system service
  • Moisture and air removal
  • System dehydration
  • Leak testing preparation
  • Commercial HVAC service
  • Workshop and mobile service operations

Solenoid Valve Advantage

The integrated solenoid valve provides automatic protection:

  • Automatic Shut-Off: Closes when pump stops
  • Prevents Backflow: Protects system from oil contamination
  • Maintains Vacuum: Preserves vacuum when pump is off
  • Professional Standard: Essential for quality evacuations
  • Convenience: No manual valve operation required

Two-Stage vs Single-Stage

Two-Stage (This Model):

  • Deeper vacuum (15 microns)
  • Faster evacuation
  • Better moisture removal
  • Professional standard
  • Ideal for critical applications

Single-Stage:

  • Lower ultimate vacuum
  • More economical
  • Suitable for basic evacuations

Related Vacuum Pumps

90068 Series:

Replacement Parts & Accessories

Vacuum Pump Oil

Why Choose Mastercool Vacuum Pumps?

  • Professional Quality: Built to demanding standards
  • Two-Stage Performance: Deep vacuum capability
  • High Displacement: Fast evacuation times
  • Solenoid Valve: Automatic protection
  • Vacuum Gauge: Monitor performance
  • Reliable Motor: 3/4 HP for consistent power
  • Dual Voltage: 50/60Hz operation
  • European Standard: Schuko power cord
  • Durable Construction: Long service life

Perfect For

  • HVAC/R service technicians
  • Air conditioning installers
  • Refrigeration technicians
  • Commercial HVAC service
  • System evacuation and dehydration
  • Workshop environments
  • Mobile service operations
  • European market (220V 50/60Hz)
  • Applications requiring deep vacuum
  • Professional installations

Operating Instructions

  1. Ensure pump oil is at correct level
  2. Connect vacuum hose to system
  3. Plug in pump (220V Schuko socket)
  4. Start pump and monitor vacuum gauge
  5. Allow system to reach target vacuum level
  6. Solenoid valve will close automatically when pump stops
  7. Disconnect and store properly

Maintenance

  • Oil Level: Check before each use
  • Oil Changes: Regular oil changes for optimal performance
  • Intake Filter: Clean or replace regularly
  • Exhaust Filter: Check and replace as needed
  • Solenoid Valve: Test operation periodically
  • Vacuum Gauge: Verify accuracy
  • Shaft Seal: Inspect for leaks
  • Storage: Store in clean, dry location
  • Pump Cover: Keep clean and secure

Understanding Micron Ratings

The 15 micron ultimate vacuum rating represents optimal laboratory conditions. Field conditions may vary due to:

  • Ambient temperature
  • Oil condition and level
  • System size and complexity
  • Hose length and diameter
  • Altitude
  • Pump maintenance condition

Regular maintenance and proper operating procedures will help achieve the best possible vacuum levels in field conditions.


Professional Quality: Mastercool vacuum pumps are built to professional standards for reliable, high-performance evacuation in demanding HVAC/R service environments. The 90068-2V-220SVB two-stage vacuum pump features 227 litre/min free air displacement (60Hz), 15 microns ultimate vacuum, integrated solenoid valve with vacuum gauge, 3/4 HP motor, and 220V 50/60Hz dual voltage operation with Schuko power cord for professional system evacuation and dehydration.

You may also like