Mastercool 90265 — Red Manual Shut-Off Valve 1/4" Flare with Flexible Hose (High Pressure)
Mastercool 90265 — Red Manual Shut-Off Valve with Flexible Hose
Professional red manual shut-off valve with 1/4" flare connections and flexible hose. Features quarter-turn ball valve operation for quick on/off control. EPA, SAE, and UL compliant for refrigerant containment. High-pressure rated for R410A and all common refrigerants. Essential accessory for controlled refrigerant charging and recovery operations.
Key Features:
- Manual Ball Valve – Quarter-turn operation for quick on/off control
- 1/4" Flare Connections – Standard SAE fittings both ends
- Flexible Hose – Easy routing and positioning
- Red Colour – High-side (discharge) identification
- High-Pressure Rated – Suitable for R410A and all refrigerants
- EPA/SAE/UL Compliant – Meets refrigerant containment standards
- Refrigerant Containment – Prevents venting during service
- Professional Quality – Built for daily HVAC/R use
Specifications:
- Model: 90265
- Type: Manual shut-off valve with flexible hose
- Valve type: Quarter-turn ball valve
- Connections: 1/4" flare both ends
- Colour: Red (high-side)
- Hose: Flexible
- Compliance: EPA, SAE, UL
- Application: Refrigerant charging and recovery
- Weight: 10 kg (shipping weight)
- SKU: 90265
- HS Code: 40093100
Use With Manifold Sets:
- 33103-M — 2-Way Brass Manifold 63mm 5 Refrigerant Scales
- 33636-M — Brass Manifold Set 63mm 5 Scales with 3 x 90cm Hoses
- 33636-E — Brass Manifold Set 63mm for R410A
Use With Recovery Machines:
- 69000-220 — Professional Refrigerant Recovery System (220V, CE Certified)
- 69000-220-TÜV — Refrigerant Recovery Unit (CE/GS-TÜV/E35-421, 220V)
Applications:
- Controlled refrigerant charging
- Refrigerant recovery operations
- System evacuation control
- Preventing refrigerant venting
- High-side manifold connections
- Professional HVAC/R service work
- EPA-compliant refrigerant handling
Why Use Manual Shut-Off Valves?
Manual shut-off valves provide precise control over refrigerant flow during charging and recovery operations. The quarter-turn ball valve allows instant on/off control, preventing refrigerant venting when disconnecting hoses. This is essential for EPA compliance and professional refrigerant handling practices. The flexible hose design allows easy routing and positioning during service operations.
Benefits:
- Quarter-Turn Operation – Fast, easy on/off control
- Prevents Venting – Close valve before disconnecting to contain refrigerant
- EPA Compliant – Meets refrigerant containment standards
- Flexible Hose – Easy routing and positioning
- High-Pressure Rated – Handles R410A and all refrigerants
- Professional Quality – Built for daily commercial use
- Red Colour Coding – Easy identification for high-side use
- Universal Compatibility – Standard 1/4" flare fittings
How to Use:
- Connect valve to manifold high-side (red) port
- Connect other end to system service port or refrigerant cylinder
- Open valve (quarter-turn) to allow refrigerant flow
- Proceed with charging or recovery operation
- Close valve (quarter-turn) before disconnecting
- Disconnect hose with minimal refrigerant loss
- Valve contains refrigerant in hose
EPA Refrigerant Containment Requirements:
EPA regulations require technicians to minimise refrigerant venting during service operations. Manual shut-off valves are essential for compliance, allowing technicians to close the valve before disconnecting hoses, thereby containing refrigerant and preventing atmospheric release.
Quarter-Turn Ball Valve Operation:
- Open Position – Handle parallel to hose, refrigerant flows freely
- Closed Position – Handle perpendicular to hose, refrigerant flow stopped
- Quick Operation – 90° turn from open to closed
- Positive Shut-Off – Ball valve provides complete seal
High-Side vs Low-Side Valves:
- High-Side (Red - 90265) – For discharge/high-pressure connections (this product)
- Low-Side (Blue) – For suction/low-pressure connections
- Centre (Yellow) – For service/centre port connections
Maintenance:
- Inspect valve operation regularly
- Check for leaks at connections
- Lubricate valve occasionally with refrigerant oil
- Replace if valve becomes difficult to operate
- Keep hose clean and free from damage
- Store properly when not in use
Safety Notes:
- Always close valve before disconnecting hoses
- Verify valve is fully open during charging/recovery
- Check for leaks after connection
- Wear safety glasses when handling refrigerant
- Follow EPA refrigerant handling regulations
Professional Quality: Mastercool manual shut-off valves are built to professional standards for reliable refrigerant containment in demanding HVAC/R service environments. EPA, SAE, and UL compliant for professional refrigerant handling.