Mastercool '69300

Mastercool 69300 — TWIN TURBO Recovery Unit 110V

£1,176.42 GBP
Skip to product information
Mastercool '69300

Mastercool 69300 — TWIN TURBO Recovery Unit 110V

£1,176.42 GBP
Shipping calculated at checkout.

Mastercool 69300 — TWIN TURBO Refrigerant Recovery System

APPROVED FOR ALL AIR CONDITIONING REFRIGERANTS INCLUDING A2L MILDLY FLAMMABLE REFRIGERANTS

Mastercool's 69300 Twin Turbo Refrigerant Recovery System is built for professionals who require high performance, efficiency, and durability in their refrigerant recovery processes. It is approved for use with all refrigerants, including mildly flammable A2L refrigerants and has recovery rates amongst the highest in the industry, making it the most powerful solution for HVAC and refrigeration recovery applications.

Unmatched Power, Precision, and Durability for Superior Refrigerant Recovery Performance

The enhanced internal structure of Mastercool's Twin Turbo Refrigerant Recovery System allows for maximum recovery capacity whilst at the same time decreasing size and weight. The design of the dual piston oil-less compressor provides maximum recovery efficiency whilst the high-volume cooling fan and condenser ensures optimal cooling efficiency which keeps the compressor working at higher capacities. A safety high pressure cut-off switch automatically stops operation if pressure levels exceed safe limits whilst the purge valve ensures 100% refrigerant removal from the condenser and recovery machine. Encased in a durable, reinforced plastic shell, Mastercool's Twin Turbo Refrigerant Recovery System is engineered to endure challenging work environments, whether for residential, commercial, or industrial tasks, all whilst delivering fast and efficient performance.

Key Features

  • Safety High Pressure Cut-Off Switch: Automatically stops operation if pressure levels exceed safe limits which protects both the user and the equipment
  • Revolutionary Dual Piston Oil-Less Compressor: Delivers maximum recovery efficiency whilst reducing size and weight
  • High Volume Cooling Fan: Prevents overheating and ensures consistent performance in high-temperature environments
  • Largest Volume Recovery Rate: In the market allowing technicians to handle demanding jobs
  • Works with All Refrigerants: Including CFCs, HCFCs, HFCs and A2L mildly flammable refrigerants (R410a, R22, etc) making it ideal for HVAC and refrigeration recovery tasks
  • Durable and Portable: Injection moulded high density polyethylene case with built-in bumper guards for enhanced impact resistance
  • Sealed Crank Case: Eliminates refrigerant loss during the recovery process

Technical Specifications

  • Model: 69300
  • Voltage: 115V / 60Hz
  • Compressor Power: ½ HP dual piston oil-less compressor
  • Operating Temperature: 32 to 122°F (0 to 50°C)
  • Material: High-Density Polyethylene (HDPE) hard plastic case
  • Compatible Refrigerants: All CFC, HCFC, HFC's and A2L mildly flammable refrigerants
  • Weight: 12 kg
  • SKU: 69300
  • HS Code: 84189910

Recovery Rates

R22:

  • Direct vapour: up to 0.63 lb/min (0.29 kg/min)
  • Direct liquid: up to 7.56 lb/min (3.43 kg/min)
  • Push pull: up to 18.3 lb/min (8.30 kg/min)

R410A:

  • Direct vapour: up to 0.70 lb/min (0.32 kg/min)
  • Direct liquid: up to 7.7 lb/min (3.49 kg/min)
  • Push pull: up to 20.2 lb/min (9.16 kg/min)

Also Available

Applications

  • HVAC refrigerant recovery
  • Commercial refrigeration service
  • Automotive A/C recovery
  • Residential A/C service
  • Heat pump service
  • R410A system recovery
  • A2L refrigerant recovery
  • High-volume recovery operations

Benefits

  • Highest Recovery Rates: Industry-leading performance for maximum productivity
  • A2L Approved: Ready for modern mildly flammable refrigerants
  • Oil-Less Compressor: No oil contamination, reduced maintenance
  • Safety Protection: High pressure cut-off prevents equipment damage
  • Efficient Cooling: High-volume fan maintains optimal operating temperature
  • Durable Construction: HDPE case with bumper guards for job site protection
  • Sealed Crank Case: Zero refrigerant loss during recovery
  • Compact Design: Maximum power in reduced size and weight
  • Professional Quality: Built for daily commercial use

Perfect For

  • HVAC/R contractors and installers
  • Commercial refrigeration technicians
  • Automotive A/C specialists
  • Workshop and service centres
  • Mobile service operations
  • Fleet maintenance facilities
  • High-volume recovery operations
  • Technicians working with A2L refrigerants

Why TWIN TURBO?

The TWIN TURBO designation refers to the revolutionary dual piston oil-less compressor design that delivers:

  • Maximum Recovery Efficiency: Dual pistons provide superior performance
  • Reduced Size and Weight: More power in a compact package
  • Oil-Less Operation: No oil contamination of recovered refrigerant
  • Longer Service Life: Less wear and tear than traditional compressors
  • Consistent Performance: Reliable operation in demanding conditions

A2L Refrigerant Compatibility

The 69300 is approved for A2L mildly flammable refrigerants, making it future-ready for modern HVAC systems:

  • R32: Common in residential A/C systems
  • R454B: R410A replacement refrigerant
  • R1234yf: Automotive A/C refrigerant
  • Other A2L Refrigerants: Approved for all mildly flammable refrigerants

Operation

  1. Connect recovery hoses to system and recovery cylinder
  2. Ensure recovery cylinder is on scale (if weighing)
  3. Power on 69300 recovery unit
  4. Open valves and begin recovery
  5. High-volume cooling fan maintains optimal temperature
  6. Monitor recovery progress
  7. Safety cut-off protects against over-pressure
  8. When complete, use purge valve to remove 100% of refrigerant
  9. Close valves and power off unit

Maintenance

  • Cooling Fan: Keep fan and vents clean for optimal cooling
  • Purge Valve: Use after each recovery to ensure complete refrigerant removal
  • Case: Clean HDPE case regularly, inspect bumper guards
  • Connections: Check hose connections for leaks
  • Storage: Store in clean, dry environment
  • Inspection: Regularly inspect for damage or wear

Safety Guidelines

  • Always wear safety glasses when recovering refrigerant
  • Ensure adequate ventilation
  • Follow proper refrigerant handling procedures
  • Do not exceed operating temperature range (32-122°F)
  • Allow high pressure cut-off to function - do not bypass
  • Use appropriate recovery cylinder for refrigerant type
  • Follow A2L refrigerant safety protocols when applicable
  • Keep unit away from ignition sources when recovering A2L refrigerants

Professional Quality: Mastercool refrigerant recovery systems are built to professional standards for reliable, high-performance refrigerant recovery in demanding HVAC/R service environments. The 69300 TWIN TURBO features revolutionary dual piston oil-less compressor technology, industry-leading recovery rates, A2L refrigerant approval, and durable HDPE construction for professional recovery operations. 115V / 60Hz.

You may also like